Skip to main content

Table 4 P300 parameters in patients with multiple sclerosis according to their cognition

From: P300 event-related potentials in patients with multiple sclerosis

Variables

Cognition

P value

Impaired

(n = 24)

Intact

(n = 26)

P 300 latency (ms)

   

 Mean ± SD

372.92 ± 30.22

307.72 ± 5.76

 < 0.001

 Range

300–417

294–318

P 300 amplitude (µV)

   

 Mean ± SD

5.95 ± 2.34

9.58 ± 1.11

 < 0.001

 Range

2.08 ± 9.8

8.1–12

  1. Significant values (p value < 0.05) are given in bold